Fiberline Composites

Products

Corporate

 

Typical electrical properties for Fiberline GRP profiles, of dry condition.

The table indicates general electrical properties valid for Fiberline GRP profiles (dry condition).

Values of specific profiles vary.
 
Electrical
properties
0o 90o O Unit Norm
Specific
resistance
    1010-1014 Ω cm VDE
0303/30-93
Surface resistance
    1010-1013 Ω VDE
0303/30-93
Disruptive
voltage
20-40 10-40   kV/mm VDE 
0303/2-74
Dielectric
constant
    0,03   DIN
53483-69
Dielectric
dissipation
factor
    <5   DIN
53483-69
Tracking
current
resistance
   
 KA: 3c
 KB:500
 KC:600
 
DIN
53480-76

0° Parallel with the longitudinal fibres of the profile.

90° Perpendicular to the longitudinal fibres of the profile.
O Direction independent.
A special polyester is used for temperatures of 150º to 180º C.

Electromagnetic transparency
Electromagnetic transparency is an important property that is utilized in numerous ways to avoid reflection of electromagnetic waves.

No sparks
Because it contains no metal, the material prevents sparks – an extremely important property when used in proximity to gasses and flammable liquids.